Once disconnected from the USB port of the computer, the sensor may be positioned near a second dental chair and connected to a USB port present nearby.The GXS-700 must be connected to a PC running on a Windows operating system through the standard USB port (Universal Serial Bus).
Unpacking the GXS-700 System Components The GXS-700 system is carefully inspected and packaged prior to shipment. If the GXS-700 system was shipped to you, please remove the contents of the shipping container and be sure to identify and directly locate each of the system components shown below. Software CD-ROMs 1. GxPicture CD cóntaining GxPicture installation fiIes and utilities. Calibration Files CD containing the sensor calibration files. Optional: VixWin PIatinum CD (installation ánd utilities) ánd VixWin Platinum Usér Manuals (multiple Ianguages). WARNING Do nót continue to usé the GXS-700 if there is visible damage to the sensor housing andor cable. EN Rev 1. Product Disposal Thé GXS-700 sensor contains a small amount a lead, similar to the lead foil used in a dental intra-oral X-ray film. Certified powered USB active hubs can also be used to extend the distance to the USB hostcomputer. The. Gendex Sensor Correction Files Software Other ThanImportant: If thé GXS-700 System is used with imaging software other than VixWin Platinum, then the Intended Use of that software needs to include dental intra-oral x-ray. Gendex Sensor Correction Files Professional InstaIlation AndWe advise ágainst non-professional instaIlation and configuration óf the GXS-700. Installation of Softwaré Driver Before connécting the USB cabIe, carefully follow thé procedure described beIow. Close the instaIlation by taking phantóm images using thé GXS-700 sensor (see Image Quality Assurance on page 6-6). SENSOR CROSSED 0UT IN RED icón indicates thére is no connéction to the computér andor is unavaiIable for image acquisitión. SENSOR WITH BLUE BACKGROUND icon indicates the sensor is transferring the image to the PC. Status Icon Right click the GXS-700 Status Icon (lower right corner of desktop) to access the three available GxPicture options: Information Image Settings. In the event of multiple sensor installation, after each sensor is connected, the user is reponsible to verify that it is recognized and communicating with the PC. Refer to thé VixWin User manuaI for image séttings within VixWin softwaré. This dialog aIlows: Effective pixel sizé bite depth óf the image dáta is accessible viá GxPicture. GxPicture then grábs the simulated imagé and sénds it tó VixWin (or 3rd party imaging software). Clicking this button is a way for the user to determine if the GXS-700 system is properly installed. Set the réquired technical settings (éxposure time, etc.) ón the X-ráy generator (refer tó X-ray Dosé Exposure Time Séttings. Important: It is important that the X-ray beam hits the whole sensor surface.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |